RevitalCore Cryo Elite Electric Cryotherapy Chamber
The RevitalCore Cryo Elite is an electric cryotherapy chamber for one or two users that reaches -110°C without liquid nitrogen. Running a recovery business on liquid nitrogen means constant refills, storage headaches, and safety paperwork that never ends. What if your chamber just plugged in and got cold? Down to -110°C, with room for one or two people, an all-glass front, interior audio, and digital controls that keep sessions running on schedule. You get the cold your clients came for, and none of the cryogen logistics your staff dreads.
-
No Nitrogen: Electric refrigeration eliminates cryogen storage, refills, and handling costs entirely.
-
Chamber Temperature: Operates from -80°C to -140°C, reaching -110°C for professional sessions.
-
Session Length: Adjustable from 2 to 4 minutes per client.
-
Cooldown Time: Approximately 60 minutes from room temperature to -80°C, one startup covers your day.
-
Capacity: Fits 1 to 2 users per session, with an estimated 60 to 80 users across 10 hours.
-
Glass Viewing: Full-glass design keeps clients comfortable and staff visibility clear.
-
Controls: Integrated digital interface with a countdown display for simple, consistent operation.
-
Audio: Interior audio system included for communication and atmosphere.
-
Access and Safety: Magnetic-card entry and an emergency-stop button for managed use.
-
Optional Upgrades: 5G, Wi-Fi, remote power control, fingerprint access, and powered glass available.
-
Power Needs: Three-phase, five-wire setup, 9kW standby and 21kW maximum draw.
-
Certifications: CE ROAS, MSDS, and ISO9001 for professional installations.
-
Built for You: Each chamber is made to order with your chosen power setup and features, with lead times of one to three months.
-
Shipping: Quoted separately after we confirm your location and installation needs.
How the RevitalCore Cryo Elite Ends Your Nitrogen Supply Chain
Every liquid nitrogen chamber comes with an invisible second business attached: sourcing, storing, handling, and paying for cryogen week after week. This chamber replaces all of it with a separate high-capacity electric refrigeration unit.
-
No liquid nitrogen required at any point in operation
- No cryogen tanks on site, no refill scheduling, no handling protocols to train around
- Refrigeration unit measures 1650 × 900 × 820 mm H × D × W, approximately 65" × 35.4" × 32.3", so it can be positioned in a service area away from the client-facing room
- Consistent cold on demand instead of temperatures that drift as a tank empties
Your operating cost becomes electricity. Predictable, budgetable, and already on your utility bill.
Why the RevitalCore Cryo Elite Whole Body Cryotherapy Chamber Reaches Professional Temperatures
A cold session depends on the chamber actually reaching temperature and staying there. This system operates across a range of -80°C to -140°C (-112°F to -220°F) and is engineered to reach -110°C for demanding professional environments.
-
Session duration adjustable from 2 to 4 minutes, so you can tailor protocols to first-timers and seasoned athletes alike
-
Initial cooling time of approximately 60 minutes from room temperature to -80°C, meaning one pre-opening startup covers your whole day
- Once cold, the chamber stays ready between clients instead of restarting from ambient
That combination of depth and stability is what separates a commercial installation from a consumer-grade cold box.
Room for One or Two Inside the RevitalCore Cryo Elite Electric Cryotherapy Chamber
Interior space is what lets you sell more than solo sessions. The chamber interior measures 2050 × 900 × 1100 mm H × D × W, approximately 80.7" × 35.4" × 43.3", and comfortably supports 1 to 2 users per session.
- Run partner sessions, teammate pairs, or coach-accompanied first visits without buying a second chamber
-
Estimated 10-hour capacity of 60 to 80 users
- External footprint of 2350 × 1400 × 1350 mm H × D × W, approximately 92.5" × 55.1" × 53.1", for straightforward room planning
All-Glass Viewing for a More Open Feel
Enclosed spaces make some people nervous. The full-glass viewing window changes the entire feel of a session.
- Expansive glass panels create an open, non-claustrophobic experience for the person inside
- Staff keep clear visibility on the client throughout the session, which matters for both safety and reassurance
- A powered glass lift is available as an option for smoother, hands-free access
Digital Controls and Countdown Display Built for Busy Operators
Your front desk staff should not need a technician's training to run a session. Everything lives in one integrated digital operating interface.
- Set chamber temperature, session time, and operating functions from a single intuitive panel
- A visible digital countdown display shows remaining session time to both the user and the operator, so nobody has to guess or watch a phone
-
Interior audio system included, supporting staff-to-client communication during the session and adding a more engaging atmosphere with music
Consistent settings mean consistent sessions.
Access Control and Safety Features for Managed Commercial Operation
Unsupervised or high-traffic facilities need more than a power switch. This chamber ships with controls that govern who uses it and how a session ends.
-
IC magnetic-card recognition access control, so only authorized clients and staff can start a session
-
Emergency-stop button for immediate intervention at any moment
-
Certified to CE ROAS, MSDS, and ISO9001 standards
Those certifications matter when you are presenting your facility to insurers, landlords, and medical partners.
Optional Smart Upgrades for Connected Facilities
Want the chamber tied into how you already run the building? Several upgrades are available at order time.
- 5G connectivity
- Wi-Fi
-
Remote power control, useful for starting the cooling cycle before staff arrive
-
Fingerprint access as an alternative to card entry
- Powered glass adjustment
Specify the combination you want when you request your quote.
Electrical Requirements You Can Plan Your Build-Out Around
Get your electrician the numbers early. This is a three-phase, five-wire installation.
- Available power configurations: 220v / 60Hz, 380V / 50Hz, 200V / 60Hz, or 460V / 60Hz
-
Standby power of 9kW, drawn while the chamber holds temperature between sessions
-
Maximum power of 21kW during peak cooling demand
Because the chamber holds cold rather than restarting all day, standby draw is the figure your day-to-day energy math actually lives on.
Planning for Commercial Use
Every facility is different. Session pricing, client volume, staffing, and operating costs all vary, so we don't publish revenue or payback estimates. If you're adding this equipment to a clinic, studio, spa, or gym, call us at (855) 975-6272 and we'll help you plan space, power, installation, and support.
Built to Order Specifically for Your Facility
This chamber is made to order. Your unit is assembled after you order it, configured to the power specification your building runs on and with the optional features you selected, rather than pulled off a shelf in whatever configuration happened to be sitting there.
- Your chosen power configuration is built in, not adapted afterward
- Optional connectivity, access, and powered glass features are integrated during assembly
- Because each chamber is produced individually, lead times typically run one to three months
It is worth the wait for equipment built around your space and power setup.
Shipping and Installation Quoted for Your Location
Shipping and installation are quoted separately and are not calculated at checkout. Select Get More Info to request a complete quotation. Once we confirm your delivery destination and any installation requirements, we send you the equipment total, shipping costs, and any requested installation charges by email. Contact Us with your site details and we will put the full picture together.
Frequently Asked Questions
| Question |
Answer |
| Does this chamber require liquid nitrogen? |
No. It uses electric refrigeration, so there is no cryogen storage, handling, or resupply. |
| How cold does it get? |
The chamber operates from -80°C to -140°C (-112°F to -220°F) and is engineered to reach -110°C for professional use. |
| How long does a session last? |
Session duration is adjustable from 2 to 4 minutes. |
| How long does it take to cool down before opening? |
Approximately 60 minutes from room temperature to -80°C. |
| How many people can use it at once? |
The recommended capacity is 1 to 2 users per session. |
| How many clients can it serve in a day? |
Estimated 10-hour capacity is 60 to 80 users. |
| What electrical supply does it need? |
Three-phase, five-wire. Available in 220v / 60Hz, 380V / 50Hz, 200V / 60Hz, or 460V / 60Hz. |
| How much power does it draw? |
9kW standby and 21kW maximum. |
| Is the refrigeration unit built into the chamber? |
No. It is a separate high-capacity unit measuring 1650 × 900 × 820 mm H × D × W, approximately 65" × 35.4" × 32.3". |
| How do clients access the chamber? |
IC magnetic-card recognition is standard. Fingerprint access is available as an option. |
| What safety controls are included? |
An emergency-stop button, plus full-glass visibility for staff monitoring throughout the session. |
| Is audio included? |
Yes, an interior audio system is included as standard. |
| What optional features can I add? |
5G connectivity, Wi-Fi, remote power control, fingerprint access, and powered glass adjustment. |
| What certifications does it carry? |
CE ROAS, MSDS, and ISO9001. |
| How long until my chamber arrives? |
Each unit is made to order for your facility, with lead times typically running one to three months. |
| Is shipping included in the price? |
No. Shipping and installation are quoted separately. Select Get More Info for a complete quotation. |
Product Specs
| Specification |
Detail |
| Brand |
RevitalCore |
| Model |
RC Cryo Elite |
| SKU |
RC-CRYO-CF-110-1 |
| Type |
Cryotherapy Chamber |
| Cooling Technology |
Electric Refrigeration, No Liquid Nitrogen Required |
| Chamber Temperature |
-80°C to -140°C (-112°F to -220°F) |
| Session Duration |
Adjustable from 2–4 Minutes |
| Initial Cooling Time |
Approximately 60 Minutes from Room Temperature to -80°C |
| Recommended Capacity |
1–2 Users per Session |
| Estimated 10-Hour Capacity |
60–80 Users |
| External Dimensions |
2350 × 1400 × 1350 mm H × D × W (approximately 92.5" × 55.1" × 53.1") |
| Interior Chamber Dimensions |
2050 × 900 × 1100 mm H × D × W (approximately 80.7" × 35.4" × 43.3") |
| Refrigeration Unit Dimensions |
1650 × 900 × 820 mm H × D × W (approximately 65" × 35.4" × 32.3") |
| Refrigeration Configuration |
Separate High-Capacity Refrigeration Unit |
| Electrical Configuration |
Three-Phase, Five-Wire |
| Available Power Configurations |
220v / 60Hz, 380V / 50Hz, 200V / 60Hz, or 460V / 60Hz |
| Standby Power |
9kW |
| Maximum Power |
21kW |
| Viewing Window |
Full-Glass Design |
| Powered Glass Lift |
Optional |
| Interior Audio System |
Included |
| Access Control |
IC Magnetic-Card Recognition |
| Optional Connectivity |
5G, Wi-Fi, Remote Power Control and Fingerprint Access |
| Control System |
Integrated Digital Operating Interface |
| Safety Control |
Emergency-Stop Button |
| Certifications |
CE ROAS, MSDS, ISO9001 |